UL 1716

零售价

市场价


重量

数量
-
+

库存

隐藏域元素占位

UL 1716

所属分类:

UL电线

DOWNLOAD
  • 产品详情

    APPLIANCE WIRING MATERIAL
    Subj.758 Section 1 Page 1716 Issued:1977-05-25
    Revised:2012-02-01
    Style 1716 Single conductor with extruded insulation.

    Rating150 deg C, 150 Vac, Horizontal flame, Oil Res 60 deg C or 80 deg C (opt), Gasoline Resist (opt)
    ConductorSolid or stranded or Litz cable magnet wire, R/C (OBMW2) magnet wire rated min 150 deg. C. AWG size to be determined by the Resistance Test per UL 1581. In addition, tinned copper may be employed when FEP insulation is used.
    InsulationFEP or PFA or PTFE, TFE
    50-20 AWG5.5 mils min average5 mils min at any point
    19-15 AWG8 avg7 min
    14-10 AWG13 avg12 min
    9-6 AWG20 avg18 min
    May extrude FEP in two or three layers.
    AssemblyEach single on magnet wire strand is cabled together other magnet wire strands to form a conductor.
    ShieldOptional.
    CoveringOptional, FEP, or PFA, 0.005 in or heavier or PTFE (extruded or tape wrapped) 0.005 in or heavier.
    StandardAppliance Wiring Material UL 758.
    MarkingGeneral.
    UseInternal wiring of electronic equipment, such as electronic computers and business machines, where not subjected to movement or mechanical damage. May also be used for further processing in cables and lead wire for UL 1950 applications. Tags may indicate the following:"300 peak Volts for Electronic Use Only"."Suitable for immersion in gasoline; gasoline vapor; and 60 deg. C or 80 deg. C in Oil".

    UL and the UL Logo are trademarks of UL LLC © 2023