UL 20352

零售价

市场价


重量

数量
-
+

库存

隐藏域元素占位

UL 20352

所属分类:

UL电线

DOWNLOAD
  • 产品详情

    APPLIANCE WIRING MATERIAL
    Subj.758 Section 2 Page 20352 Issued:1984-11-07
    Revised:2012-12-11
    Style 20352 Multiple-conductor cable using non-integral jacket

    Rating60 deg C, 600 Vac, Cable flame.
    Conductor40 AWG minimum, solid or stranded.
    Insulated ConductorLabeled or complying with manufacturer's AWM procedure.
    AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. Cable may be either straight or wound in retractile form.
    ShieldOptional, may be over one or more of the insulated conductors or applied over the assembly.
    JacketExtruded TPU.
    Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
    0.700 inch or less45 mils36 mils
    0.701-1.000 inch60 mils48 mils
    1.001-1.500 inch80 mils64 mils
    1.501-2.500 inch110 mils88 mils
    2.501 inch or larger140 mils112 mils
    StandardAppliance Wiring Material UL 758.
    MarkingGeneral.
    UseAs internal wiring or external interconnection of electronic equipment.

    UL and the UL Logo are trademarks of UL LLC © 2023