UL 10842

零售价

市场价


重量

数量
-
+

库存

隐藏域元素占位

UL 10842

所属分类:

UL电线

DOWNLOAD
  • 产品详情

    APPLIANCE WIRING MATERIAL
    Subj.758 Section 1 Page 10842 Issued:2004-03-01
    Revised:2019-11-07
    Style 10842 Single conductor with non-integral jacket

    Rating60 deg C, 1000 Vac, Cable flame.
    InsulationLabeled or complying with manufacturer's AWM Procedure.
    ShieldOptional.
    CoveringOptional.
    JacketPUR
    dia in inches
    0.700 or less30 mils min average24 mils minimum at any point
    0.701-1.000 dia45 avg36 min
    1.001-1.500 dia60 avg48 min
    1.501-2.500 dia80 avg64 min
    StandardAppliance Wiring Material UL 758.
    MarkingGeneral.
    UseInternal wiring and external interconnection of electronic equipment.