    APPLIANCE WIRING MATERIAL
    Subj.758 Section 1 Page 10311 Issued:1997-06-10
    Revised:2012-04-25
    Style 10311 Single Conductor with Extruded Insulation.

    Rating200 deg C, 150 Vac, Horizontal flame.
    Conductor40 AWG - 6 AWG solid or stranded or litz cable magnet wire, R/C (OBMW2) magnet wire. AWG size to be determined by the Resistance Test
    InsulationExtruded FEP or Extruded PFA or Extruded PTFE, TFE
    40-20 AWG conductor size5.5 mils minimum average thickness5 mils minimum thickness at any point
    19-15 AWG8 avg7 min
    14-10 AWG13 avg12 min
    9-6 AWG20 avg18 min
    Tinned copper may be employed when FEP insulation is used.
    AssemblyEach single magnet wire strand is cabled together, other magnet wire strands to form a conductor.
    StandardAppliance Wiring Material UL 758.
    MarkingGeneral.
    UseInternal wiring of electronic equipment, such as electronic computers and business machines, where not subjected to movement or mechanical damage. May also be used for further processing in cables and lead wire for UL 1950 applications. Tags may indicate the following: "300 peak Volts for Electronic Use Only". "Suitable for immersion in gasoline; gasoline vapor; and 60 deg. C or 80 deg. C in oil".