UL 21126

零售价

市场价


重量

数量
-
+

库存

隐藏域元素占位

UL 21126

所属分类:

UL电线

DOWNLOAD
  • 产品详情

    APPLIANCE WIRING MATERIAL
    Subj.758 Section 2 Page 21126 Issued:2001-01-24
    Revised:2019-11-07
    Style 21126 Multiple conductor cable using extruded non-integral jacket

    Rating80 deg C, 30 Vac, Horizontal flame.
    Conductor36 AWG minimum, solid or stranded.
    InsulationLabeled or complying with manufacturer's AWM Procedure. The designations of all styles of individual conductors used in making up the cable assembly shall be available.
    AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; thermoplastic covering, or thermoplastic-tape wrap.
    ShieldOptional - Location not specified.
    JacketExtruded TPU
    major dia. in inches
    0.700 or less30 mils min average24 mils min at any point
    0.701-1.0004536
    1.001-1.5006048
    1.501-2.5008064
    2.501-4.00011088
    4.001 and larger140112
    StandardAppliance Wiring Material UL 758.
    MarkingGeneral.
    UseInternal wiring.

    UL and the UL Logo are trademarks of UL LLC © 2023

返回列表

上一页

下一页