UL 21082

零售价

市场价


重量

数量
-
+

库存

隐藏域元素占位

UL 21082

所属分类:

UL电线

DOWNLOAD
  • 产品详情

    APPLIANCE WIRING MATERIAL
    Subj.758 Section 2 Page 21082 Issued:2000-03-23
    Revised:2014-01-16
    Style 21082 Jacketed Cable.

    Rating150 deg C, 30 Vac, Horizontal flame.
    InsulationLabeled or complying with manufacturer's AWM Procedure and having a minimum rating of 150 C and 30 V.
    AssemblyTwo or more twisted singles or groups of twisted singles twisted together or two or more conductors or groups may be laid parallel to form flat, oval, or round cables. If more than one group is used, groups may also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
    ShieldOptional
    JacketETFE
    dia of core assembly under jacketMinimum average thicknessMinimum thickness at any point
    0.425 inch or less15 mils13 mils
    0.426-0.700 inch30 mils26 mils
    0.701-1.500 inch45 mils40 mils
    1.501-2.500 inch60 mils55 mils
    2.501 inch and larger90 mils82 mils
    StandardAppliance Wiring Material UL 758.
    MarkingGeneral.
    UseInternal wiring of appliances or electronic equipment, Class 2 Circuits only, where not subjected to movement or mechanical damage.

    UL and the UL Logo are trademarks of UL LLC © 2023

返回列表

上一页