    APPLIANCE WIRING MATERIAL
    Subj.758 Section 2 Page 20711 Issued:1991-09-04
    Revised:2011-09-27
    Style 20711 Multiple-conductor cable using non-integral jacket

    Rating200 deg C, 300 Vac, Horizontal Flame.
    Insulated ConductorLabeled or complying with manufacturer's AWM Procedure .
    AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. All insulated conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted insulated conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermosplastic-tape wrap.
    ShieldOptional.
    JacketExtruded FEP.
    Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
    0.425 inch or less10 mils8 mils
    StandardAppliance Wiring Material UL 758.
    MarkingGeneral.
    UseInternal wiring of appliances or electronic equipment.