UL 20279

零售价

市场价


重量

数量
-
+

库存

隐藏域元素占位

UL 20279

所属分类:

UL电线

DOWNLOAD
  • 产品详情

    APPLIANCE WIRING MATERIAL
    Subj.758 Section 2 Page 20279 Issued:1983-10-13
    Revised:2012-02-27
    Style 20279 Multiple-conductor cable using non-integral jacket

    Rating80 deg C, 30 Vac, Cable flame.
    Conductor36 AWG - 16 AWG, solid or stranded.
    InsulationLabeled or complies with manufacturer's AWM Procedure.
    AssemblyTwo to fifty conductors - Two to eight conductors may be laid parallel or twisted together. Nine or more conductors shall be twisted together. Lay of insulated conductors not specified, but with a twist opposite in direction to the direction in which the helical cord is wound. Cable may be either straight or coiled or in the form of a helix.
    ShieldOptional.
    JacketExtruded TPU
    Dia of cable under jacketMinimum average thicknessMinimum thickness at any point
    0.425 inch or less30 mils24 mils
    0.426 - 0.700 inch45 mils36 mils
    0.701 - 1.500 inch60 mils48 mils
    StandardAppliance Wiring Material UL 758.
    MarkingGeneral.
    UseInternal wiring or external interconnection of appliances or electronic equipment.

    UL and the UL Logo are trademarks of UL LLC © 2023

返回列表