UL 10729

零售价

市场价


重量

数量
-
+

库存

隐藏域元素占位

UL 10729

所属分类:

UL电线

DOWNLOAD
  • 产品详情

    APPLIANCE WIRING MATERIAL
    Subj.758 Section 1 Page 10729 Issued:2003-09-26
    Revised:2019-11-07
    Style 10729 Single conductor cable using extruded non-integral jacket

    Rating80 deg C, 30 Vac, Horizontal flame.
    Conductor36 AWG - 2000 kcmil, solid or stranded.
    InsulationLabeled or complying with manufacturer's AWM Procedure.
    AssemblyOne insulated conductor to form a round or flat cable. Assembly Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid, paper, nylon, oriented polyethylene terephthalate; thermoplastic covering, thermoplastic-tape wrap.
    ShieldOptional.
    CoveringOptional, extruded PVC or other thermoplastic covering may be extruded over the conductor assembly (with or without shields), 4 mil minimum average thickness.
    JacketExtruded TPU
    major dia in inches
    0.350 or less15 mils min average12 mils min at any point
    0.351-0.700 dia3024
    0.701-1.000 dia4036
    1.101-1.500 dia5448
    StandardAppliance Wiring Material UL 758.
    MarkingGeneral.
    UseInternal wiring.