    APPLIANCE WIRING MATERIAL
    Subj.758 Section 2 Page 20280 Issued:1983-10-13
    Revised:2013-08-29
    Style 20280 Multiple-conductor cable using non-integral jacket

    Rating80 deg C, 300 Vac, Cable flame.
    Conductor36 - 12 AWG, solid or stranded.
    InsulationLabeled or complies with manufacturer's AWM Procedure.
    AssemblyTwo to fifty conductors; different conductor sizes may be used in one cord. Two to eight conductors may be laid parallel or twisted together. Nine or more conductors shall be twisted together. Lay of insulated conductors not specified, but with a twist opposite in direction to the direction in which the helical cord in wound. Cable may be either straight or coiled or in the form of a helix.
    ShieldOptional.
    Jacketextruded TPU
    Diameter of cable under jacket in inchesMinimum average thickness in milsMinimum thickness at any point in mils
    0.700 or less3024
    0.701-1.0004036
    1.001-1.5006048
    1.501-2.5008064
    StandardAppliance Wiring Material UL 758.
    MarkingGeneral.
    UseInternal wiring or external interconnection of appliances or electronic equipment.