UL 10556

零售价

市场价


重量

数量
-
+

库存

隐藏域元素占位

UL 10556

所属分类:

UL电线

DOWNLOAD
  • 产品详情

    APPLIANCE WIRING MATERIAL
    Subj.758 Section 1 Page 10556 Issued:2001-05-31
    Revised:2011-10-30
    Style 10556 Single Conductor with extruded insulation.

    Rating150 deg C, 300 Vac, Horizontal flame.
    Conductor50 AWG - 8 AWG, solid or stranded.
    InsulationExtruded FEP
    Thickness in accordance with the Table below
    Conductor SizeMin. Avg. thicknessMin. thickness at any point
    AWGmilsmils
    50-151211
    14-81513
    StandardAppliance Wiring Material UL 758.
    MarkingGeneral.
    UseFor internal wiring of appliances.